IEQ-7 ELECTRIC LIGHTING LEVELS

 

Technical Clarification

Electric lighting levels and 'Shell & Core' spaces

Technical Clarification Number
IEQ7-T-OB1-0361

Guidance
2012-01-10

The following guidance is provided for spaces delivered as ‘Shell & Core’, as defined in the Green Star SA Office v1 Technical Manual.

For spaces delivered as ‘Shell & Core’, where no luminaires are provided, as evidenced through the provision of a fully documented design within the tender documentation (Design rating) or as installed As Built documentation and commissioning reports (As Built rating), compliance with the Credit Criteria cannot be demonstrated.

 

Erratum

Green Star SA - Office v1 Technical Manual: Page 77

Erratum Number
IEQ7-E-OB1-0344

Guidance
2011-11-08

Documentation Requirement, documentation description, delete paragraph: “As built reflected ceiling plan (RCP) drawings for each typical ceiling layout, marked up to demonstrate compliance with the Credit Criteria, with the location, type and expected maintained illuminance of all luminaries clearly indicated”.

Replace with paragraph: “As built reflected ceiling plan (RCP) drawings for each typical ceiling layout demonstrating;
Where compliance is demonstrated through design implementation:
- The office UA spaces (with areas) modelled in the illuminance calculations.
Where compliance is demonstrated through measurement:
- All measurement locations demonstrating that measurements were conducted on a grid of no more than 1m x 1m, with all measurements taken at least 0.5m away from a window
- The maintained illuminance measured at the measurement locations."

 

Technical Clarification

Documentation clarification

Technical Clarification Number
IEQ7-T-OB1-0343

Guidance
2011-11-08

Where compliance is demonstrated through design (Design rating) or design implementation (As Built rating), and the ‘Short Report’ contains illuminance calculations demonstrating the maximum maintained lighting levels for each layout, the working plane used and compliance with the percentage UA requirements, it is not necessary to include ‘Isometric lighting measurement drawings’. These may be excluded from the ‘Documentation Requirements’ of the Green Star SA Office v1 Technical Manual.

 

 