EMI-7 LIGHT POLLUTION

 

Technical Clarification

Alternative approach: Lighting Pollution Modelling Report

Technical Clarification Number
EMI7-T-OB1-0872

Guidance
2015-02-02

Where a Lighting Pollution Modelling Report is provided as part of a short report including:
• modelling results clearly demonstrating that all related areas and light fittings are included in the simulations
• and identify all areas area(s) that does not exceed the minimum requirements of CIBSE LG6 for illuminance levels

Then it is not required that the Tender drawing(s) and or As Built drawing(s) are marked up showing the area(s) that do not exceed the minimum requirements of CIBSE LG6 for illuminance levels. However the location and type of all external luminaires should still be marked up on the Tender drawing(s) and As Built drawing(s) to assist in demonstrating that all luminaires have been included in the modelling.

Note that this TC only applies to project teams that choose to demonstrate compliance with the credit criteria through modelling.

 

Credit Interpretation Request

Lack of photometric data for custom façade lighting

Credit Interpretation Request Number
EMI7-T-OB1-0668

Ruling
2013-04-22

It is deemed acceptable for project teams to build a mock-up and measure the luminance (candelas/m²) of the custom façade lighting that doesn’t contain photometric data.

If the luminance results comply with Green Star SA requirements and the project team pursues the credit point, these confirmed results need to be submitted as additional information towards the project submission in order to prove compliance with the 10 candelas/m² requirement.

The project team should note that all other credit requirements remain as per the technical manual, technical clarifications, credit interpretations requests and errata found on the GBCSA website.

 

Erratum

Green Star SA - Office v1 Technical Manual: Page 338

Erratum Number
EMI7-E-OB1-0434

Guidance
2012-03-14

Documentation Requirements, Description of documentation, under 'Tender drawing(s)' replace "Site plan indicating the location and type of all external luminairies, and marked up to show the area(s) that does not exceed the minimum requirements of CIBSE LG6 for illuminance levels" with "Site plan indicating the location and type of all external luminaires and marked up with illuminance level(s) demonstrating that the minimum requirements of CIBSE LG6 are not exceeded".

AND

Documentation Requirements, Description of documentation, under 'As built drawing(s)' replace "Site plan indicating the location and type of all external luminairies, and marked up to show the area(s) that does not exceed the minimum requirements of CIBSE LG6 for illuminance levels" with "Site plan indicating the location and type of all external luminaires and marked up with illuminance level(s) demonstrating that the minimum requirements of CIBSE LG6 are not exceeded".

 

Erratum

Green Star SA - Office v1 Technical Manual: Page 338

Erratum Number
EMI7-E-OB1-0398

Guidance
2012-01-26

Documentation Requirements, description of documentation, under 'Tender drawing(s)', add additional dot point "Where lighting is directed at a façade or structure, drawings with sections showing the set angle of the fitting(s) to ensure that light does not spill past the non-transparent surface of the facade or structure into the sky hemisphere".

AND

Documentation Requirements, description of documentation, under 'As built drawing(s)', add additional dot point "Where lighting is directed at a façade or structure, drawings with sections showing the set angle of the fitting(s) to ensure that light does not spill past the non-transparent surface of the facade or structure into the sky hemisphere".

 

Erratum

Green Star SA - Office v1 Technical Manual: Page 337

Erratum Number
EMI7-E-OB1-0304

Guidance
2011-08-08

Documentation Requirements, description of documentation, Short Report, first bullet point, delete text "or neighbouring properties".

 

 