Erratum
Credit Criteria IEQ-4 Daylight
Erratum Number
IEQ4-E-RC1 -1258
Guidance
2016-02-08
Under credit criteria replace the second bullet point with the following, ‘60% of the nominated area has a Daylight Factor of at least 2.5% or Daylight Illuminance (DI) of at least 250 lux, as measured at 720mm above finished floor level (AFFL) under a Clear Design Sky.'
Technical Clarification
Alternative Documentation: Daylight Modelling Report
Technical Clarification Number
IEQ4-T-RC1-0871
Guidance
2015-02-04
When a Daylight Modelling Report is provided including:
• legible floor plan outputs from the daylight modelling for each plan area claimed to have either a DF of not less than 2.0%, or a DI of at least 250 Lux and
• a summary table that identifies all spaces within the building’s UA, nominates spaces that comply and their area, identifies the DF or DI value within those spaces, and provides calculations to confirm that compliant areas jointly contribute to the claimed percentage of the UA, then it is not required to overlay results on the architectural drawings, this requirement is specific to the hand calculation method only.
Erratum
Green Star SA - Retail Centre v1 Technical Manual: Page 72
Erratum Number
IEQ4-E-RC1-0293
Guidance
2011-08-08
Documentation Requirements, Description of Documents, heading Façade drawings delete: "(drawings should preferably be isometric, not 3D)"
AND
Documentation Requirements, Description of Documents, heading Roof drawings delete: "(drawings should preferably be isometric, not 3D)"
Erratum
Green Star SA - Retail Centre v1 Technical Manual: Page 71
Erratum Number
IEQ4-E-RC1-0155
Guidance
2011-01-06
Documentation Requirements, Documentation Table, Design and As Built sections, change the first bullet point to read "Daylight modelling report OR short report". Also, delete the "OR" under the first bullet point and delete the second bullet point which reads "Short report".
Erratum
Green Star SA - Retail Centre v1 Technical Manual: Page 72
Erratum Number
IEQ4-E-RC1-0156
Guidance
2011-01-06
Documentation Requirements, Description of Documentation, Short Report, add a fifth bullet point to read "Highlighting the size of the calculation grid used in the model."