Follow

GENERAL

Technical Clarification

Revised Innovation points: 10 Innovation points + additional 5 SEC Innovation points (15 in total) 

Technical Clarification Number 

INN-T-INT1-2266


Guidance

2020-03-17


Projects can only submit and achieve up to a total of 10 Innovation points + additional *5 SEC Innovation points (15 in total) for:

  • Office v1.1 submissions (in South Africa and all other African countries for which Local Context Reports have been written) 
  • CUSTOM Tool submissions
  • Retail v1 submissions (in South Africa and all other African countries for which Local Context Reports have been written)
  • PEB v1 submissions (in South Africa and all other African countries for which Local Context Reports have been written)
  • MUR v1 submissions (in South Africa and all other African countries for which Local Context Reports have been written)
  • Interiors v1 submissions (in South Africa and all other African countries for which Local Context Reports have been written)

* This is in addition to a project SEC rating i.e. a project can achieve a SEC rating. The 5 SEC Innovation points are provided to promote and recognise the extra ordinary effort that projects go to achieve SEC points.

______________________________________________________________________

Erratum
Glossary>Domestic Hot Water
Technical Clarification Numbers
GEN-00-E-INT1-2091
Guidance
2016-10-24

Add to Glossary:
"Domestic Hot Water - Domestic Hot water is defined as occupant amenity use (washing hands, bathing, showering, washing dishes, and/or space heating). Thus Domestic Hot Water will not include water for drinking."

-----------------------------------------------------------------------------------

Technical Clarification

Glossary/Fitout Definition 

GEN-E-INT1-1398

2016-06/09

Fitout – development of an internal space into a state suitable for its intended use. Through the installation of ceilings, floors, furnishings, and partitions of a building, as well as the installation of all required building services and in relation to the agreements and lease negotiations between the landlord/building owner and tenant.

-----------------------------------------------------------------------------------

Technical Clarification

External areas and basement calculations for Materials credit

GEN0-T-INT1-1420

2016-05-24

The GBCSA provided the following clarification regarding the external areas/ basement are included in the flooring, wall covering and furniture calculations under the material category for tenant fit outs that include the entire building;

The Tenant is required to define the projects GLA upfront and throughout the submission. This will establish consistency as to which credits can or cannot be targeted by the project team as well as which credits will become non-applicable.

Please see GLA definition in glossary as well as TCE GEN0-E-INT1-1302.

The project will need to define if it was an integrated fit out or shell and core base building fitout;
Integrated Fitout - A fitout where the tenancy design and construction is fully coordinated with the base building design and construction. This includes finishes, services and fitout to all areas, both common and fitout-specific, with services fully installed at each floor. The definition of integrated fitout for purposes of Green Star SA is a fitout space where; All ceilings, floor coverings, lighting systems, mechanical, electrical and hydraulic services, partition walls, and finishes are installed, fit for purpose for the fitout occupant, prior to leasing.
Shell and core fitout- A space that, prior to fitting out, was delivered with: No ceilings, floor coverings, lighting systems and partition walls, and
Ducts from air supply and return risers finish within 1m of the face of the riser.

 

___________________________________________________________________

Technical Clarification

Definition of Assembly (Glossary) 

GEN0-E-INT1-1397

2016-05-06

The putting together of manufactured parts to make a completed product, to perform a specific function and capable of disassembly without destruction.​​

​Refer to Page 7 of MAT-3 for what is covered in Assemblies.

_____________________________________________________________

 

Technical Clarification

Definition of Net Lettable Area (NLA)

GEN0-E-INT1-1302

2016-02-24

Net Lettable Area (NLA) is the area which is reserved exclusively for the tenant, and excludes common areas. NLA (measured in square metres) is the floor space between the internal finished surfaces of permanent internal walls and the internal finished surfaces of dominant portions of the permanent outer building walls.

______________________________________________________________________

Technical Clarification

General

GEN0-E-INT1-1244

2015-07-13

Page 42, Credit list, under Emissions Category, Emi-1 should read Impacts from refrigerants and insulants and Emi-2 should be Light Pollution

______________________________________________________________________

Technical Clarification

General

GEN0-E-INT1-1245

2015-07-13

Page 45, Summary of credit categories, under the Innovation category, delete the word ‘PILOT’ in the 1st sentence

Was this article helpful?
0 out of 0 found this helpful
Have more questions? Submit a request

Comments