Erratum
General Modelling Parameters, Simulation Package
Erratum Number
ENE1-E-OB1-1343
Guidance
2016-03-18
In the Energy modelling protocol under General Modelling Parameters, Simulation Package, Requirements, delete the following wording, 'Passed the BESTEST simulation software validation test' and replace it with the following wording:
- Passed the BESTEST1 validation test; or
- The European Union draft standard EN13791 July 2000; or
- Be tested in accordance with ANSI/ASHRAE Standard 140-2001.
Please contact the Green Building Council of South Africa if none of the above options can be complied with.
Technical Clarification
Energy Modelling Protocol Office Version 1.1, Section 6.7 – Extract and miscellaneous fans
Technical Clarification Number
ENE1-T-OB1 -1225
Guidance
2016-01-21
If the project team claims a maximum of 50% energy savings for carbon monoxide sensors then it is not required that the project team provide a further calculation to prove the saving. However should the project team claim a saving greater than 50% then it is required that additional information and a detailed calculation is provided per the calculation methodology included within the modelling protocol.