IEQ-4 DAYLIGHT

Technical Clarification

Credit Criteria IEQ-4 Daylight Glare Control

TC  Number

IEQ4-T-INT1 -1738

Guidance

2017-02-10

Under section 2 Daylight Glare Control this section may be made not-applicable where tenants have no exterior windows or blinds and no direct daylight glare control measures are required is conditionally approved. Project team cannot be awarded 1 point automatically.

The following documentation needs to be provided in order to claim this section not-applicable:

  1. As Built drawings showing location of nominated area and surrounding area layout.
  2. As Built drawings showing solid and glazed walls of the nominated area.

____________________________________________________________________________________

Erratum

Credit Criteria IEQ-4 Daylight

Erratum Number

IEQ4-E-INT1 -1258

Guidance

2016-02-08

Under credit criteria replace the second bullet point with the following, 'A minimum of 30% of the nominated area meets a Daylight Illuminance (DI) of at least 250 lux, as measured at 720mm above finished floor level (AFFL) under a Clear Design Sky'

 